cat8 penumbra catheter

Orange, California N Engl J Med. INDIGO Aspiration Tubing: As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump. This has allowed expansion of the use of the Indigo System in patients with coronary and peripheral vascular thrombotic occlusions. 2: Add Disclosures: Consultant to Penumbra, Inc. A 75-year-old woman with a history of diabetes, hypertension, and dyslipidemia presented with Rutherford class 5 critical limb ischemia (CLI) due to a nonhealing ulcer. With the maximized inner diameter of 0.082 and a 7 French outer diameter, CAT7 is 93% the size of CAT8, now with a lower profile. Penumbra CAT8XTORQ115 CAT8 Indigo System Aspiration Catheter 8F Item Past Expiration. If the cause cannot be determined, withdraw the device or system as a unit. Also find Catheter price list from verified suppliers with contact number | ID: 23694008673 Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. Do not use petroleum base compounds, acids, caustics, or chlorinated solvents to clean or lubricate any parts. Manual aspiration suffers from diminished aspiration force as fluid fills in the syringe, potentially resulting in systemic embolization during catheter removal, as shown in the TOTAL trial published in 2015 (Figure 1).1 Subgroup analysis of patients with high thrombus burden was explored that highlighted the potential for improved outcomes. Suhail Dohad, MD, FACC The combination of intelligent aspiration and large-lumen catheter engineering form Lightning 7 and Lightning 12: the latest generation in clot removal technology. Figure 3. After IVUS, the stent was dilated to 3.75 mm. Distal posterior tibial artery emboli occlusion. Penumbra ENGINE Indication For Use 2019;140:e774-e801. The means of mains disconnect is to remove the power cord. Warnings Do not use the INDIGO Aspiration System with a pump other than a Penumbra Aspiration Pump. Launches Indigo System Lightning 12 in U.S. Appoints Corey L. Teigen, M.D., as Chief Scientific Officer and James F. Benenati, M.D., FSIR, as Chief Medical Officer Penumbra, Inc. (NYSE: PEN), a global healthcare company focused on innovative therapies, today announced its next phase for vascular franchise growth with U.S. commercial availability of the Indigo System Lightning 12 and . Ultrasound-guided access was obtained through the right femoral vein. The combination of computer-aided aspiration and large-lumen catheter engineering form Lightning 7 and Lightning 12: the latest generation in clot removal technology. Do not use in oxygen rich environment. o The Penumbra Indigo System Separator is intended for use with our Indigo System's family of catheters to enable the removal of a wide range of thrombus. Final angiography was performed, showing complete resolution of the underlying lesion (Figure 2). Resterilization and/or reuse may result in ineffective catheter coating lubrication, which may result in high friction and the inability to access the target vasculature location. Penumbra's CAT family of catheters is engineered to be robust, trackable, atraumatic, and well suited to the peripheral anatomy where clots can form in long segments. The PENUMBRA ENGINE is indicated as a vacuum source for Penumbra Aspiration Systems. Thrombus aspiration in patients with high thrombus burden in the TOTAL trial. 2023 Bryn Mawr Communications II, LLC. Most recently, Penumbra launched Lightning Intelligent Aspiration which enables physicians to focus on optimizing thrombus removal using the system's unique clot detection mechanism. Reuse may result in canister cracking or vacuum filter blockages, which may result in the inability to aspirate. S. Jay Mathews, MD, MS, FACC Indication For Use The low-profile catheter and Penumbra . The patient received a 3.5- X 38-mm everolimus-eluting stent (Synergy drug-eluting stent [DES], Boston Scientific Corporation) with postdilation optimized by intravascular ultrasound (IVUS) and was then sent to the step-down unit. We expect the results to further refine and improve our technique for mechanical aspiration and fine-tune the use of CAT RX for patients with high thrombus burden. The INDIGO SEPARATOR 4 is not intended for use as a guidewire. Due to continual vomiting, an electrocardiogram was obtained that showed an acute MI. 3. The initial angiogram confirmed an occlusion with extensive thrombus burden of a dominant left circumflex artery and TIMI 0 flow (Figure 1). Indigo Disposable Separator 8, 150 cm Length, 0.072 in. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. Final angiographic result of SVG. Angiography of the posterior tibial artery revealed embolization to the heel resulting in no flow to the foot (Figure 1). The safety and effectiveness of this device for use in the treatment of ST-Elevation Myocardial Infarction (STEMI) has not been established. The atraumatic, low-profile design of CAT RX allowed for ease of deliverability through the freshly placed stent into the PDA when the patient was in critical condition. Get Penumbra Cat 8 in Secunderabad, Hyderabad, Telangana at best price by Zephyr Technologies. Presented at: Vascular InterVentional Advances (VIVA); November 47, 2019; Las Vegas, Nevada. gtag('config', 'UA-18982160-1'); Penumbra Inc .cls-1{fill:#a6a699;}.cls-2{fill:#b5121b;}.cls-3{isolation:isolate;fill:url(#linear-gradient);}. Disclosures: None. Figure 1. These pages are not intended for patients or for members of the general public. Remove and service the Penumbra ENGINE if liquids or solids have been drawn into the Penumbra ENGINE. Potential Adverse Events Throughout each case, Lightning provides procedural feedback via audio visual cues. Penumbra System CAT8 INDIGO System Aspiration Catheter 8 - XTORQ - 8Fr x 115cm - Non-Expired: 8Fr x 115cm 0: Contact Us: RBY2C0305 5, 19. Caution: Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. Each vessel was wired sequentially, delivering power aspiration via CAT RX to the site of each thrombus. Use of LIGHTNING Aspiration Tubing adjacent to other equipment should be avoided because it could result in improper operation. Ruby Coil, POD, and Packing Coil are large-volume coils designed for embolization of the peripheral arterial and venous systems. Penumbra ENGINE Intended Use The Indigo Separator is advanced and retracted through the corresponding size Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip. Penumbra System BENCHMARK Delivery Catheter - MP - 6Fr x .071" x 105cm - Non-Expired: 6Fr x .071" x 105cm $550.00. When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove the thrombus. Warnings The Indigo system CAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, trackable, atraumatic and well suited for the peripheral anatomy. Final angiogram with complete TIMI 3 flow after the use of CAT RX. To prevent fire or shock hazard, use a replacement power cord of equal rating. The pulmonary capillary wedge pressure is 10 mmHg. This website is intended for US audience only. The Penumbra Indigo System Separator is intended for use with our Indigo Systems CAT family of catheters to enable the removal of a wide range of thrombus. Potential Adverse Events Prior to use, please consult device labeling and instructions for use. Maintain a constant infusion of appropriate flush solution. The built-in microprocessor features a proprietary thrombus removal algorithm that automatically controls a valve in the tubing to provide continuous or intermittent aspiration. These pages are not intended for patients or for members of the general public. The catheters (CAT3, CAT RX*, CAT5, CAT6, CAT8, CATD) vary in diameters from 3.4 to 8 F and lengths of 50 to 150 cm to . Applicant. There were no cases of 30-day cardiovascular death or post procedural stroke. Excessive aspiration or failure to close the Indigo Aspiration Tubing valve when aspiration is complete is not recommended. The Penumbra ENGINE is intended as a vacuum source for Penumbra Aspiration Systems. $399.00 EACH. Do not resterilize or reuse. INDIGO SEPARATOR 4 is intended to be used with INDIGO CAT RX Aspiration Catheter to clear the distal end of the catheter lumen should it be blocked with thrombus. Enter your email address and we will contact you. $450.00) Model #: CAT8TORQ85 OEM: Penumbra System Expiration Date: 2022 Size: 8Fr x 85cm . Unit may overheat and shut off or fail to restart if run for extended periods without airflow. Mechanical coronary aspiration was performed frontline with CAT RX and Penumbra ENGINE to remove the high thrombus burden. Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System.The Indigo System CAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, durable, and trackable for use in the peripheral anatomy. After one pass with CAT RX, the high thrombus burden was removed, resulting in TIMI 3 flow. Available in a selection of sizes, the CAT family can provide access to distal peripheral . Catheters & Separators. Placing guidewire too distal in the pulmonary vasculature or excessive manipulation of aspiration/guiding catheter in the smaller, peripheral, and segmental pulmonary artery branches can result in vessel perforation. Lightning 12 and Lightning 8 expand the already broad offering of CAT8, CATD, CAT6, CAT5, and CAT3 and are paired with Penumbra ENGINE, the company's proprietary continuous, mechanical vacuum . INDIGO Aspiration Tubing: As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump. Possible complications include, but are not limited to, the following: acute vessel occlusion; air embolism; allergic reaction and anaphylaxis from contrast media or device material; anemia; arrhythmia; arteriovenous fistula; cardiac injury, cardiac perforation, cardiac tamponade; cardio-respiratory arrest; compartment syndrome; death; emboli; emergent surgery; foreign body embolization; hematoma or hemorrhage at access site; hemoptysis; hemorrhage; hypotension/hypertension; infarction leading to organ damage; infection; ischemia; myocardial infarction; neurological deficits including stroke; pneumothorax; pseudoaneurysm; renal impairment or acute renal failure from contrast media; residual thrombus due to inability to completely remove thrombus or control blood flow; respiratory failure; valvular damage; vessel spasm, thrombosis, dissection (intimal disruption), or perforation. Prior to use, please consult device labeling and instructions for use. The procedure time was short (median of 37 minutes)the shortest demonstrated so far in an investigational device exemption (IDE) trial on patients with pulmonary embolism. Her heart rate was 110 beats per minute, elevated troponin levels at 4.5 ng/mL, and elevated brain natriuretic peptide at 1,164 pg/mL. Catheters; CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm . Copyright 2023 Penumbra, Inc. All rights reserved. Flow through left circumflex artery post-CAT RX. She had a recent embolic cerebrovascular accident (CVA) with a hemorrhagic conversion and right-sided hemiparesis but was otherwise known to be very functional. This warranted the need for further innovation in the field of acute coronary syndrome.2 The goal of the Indigo System CAT RX mechanical aspiration system powered by the Penumbra ENGINE is to provide sustained aspiration for the duration of the procedure with enhanced deliverability to navigate tortuous anatomy and track to the distal coronary vasculature. 2. indicated to connect the INDIGO CAT RX Aspiration Catheters to the Penumbra Aspiration Pump. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and . Disclosures: Consultant to Penumbra, Inc. A 65-year-old man presented emergently with an inferior wall MI. Caution: Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. There was an immediate response in the clinical situation of the patient: her blood pressure stabilized into the 90s and her oxygenation improved substantially. The healthcare firm said that the Indigo CAT RX Aspiration Catheters . Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. LIGHTNING Aspiration Tubing Indication for Use We started with laser atherectomy followed by percutaneous transluminal angioplasty of the tibial peroneal trunk, peroneal artery, and posterior tibial artery. The Indigo System CAT RX with Penumbra ENGINE is an invaluable tool that is easy to set up and can provide rapid thrombectomy and immediate reperfusion. Do not use in oxygen rich environment. Penumbra's high-performance aspiration catheters. Prior to use, please consult device labeling and instructions for use. In some cases, we have also seen a reduction in glycoprotein IIb/IIIa inhibitor usage (which may be associated with higher rates of bleeding). The Penumbra ENGINE addresses the limitations of traditional treatment options by providing sustained mechanical power aspiration for the duration of the procedure to help maximize efficiency of thrombus removal. 2. Penumbra, Inc. One Penumbra Place. If such use is necessary, LIGHTNING Aspiration Tubing and the other equipment should be observed to verify that they are functioning properly. The Indigo Aspiration System is intended for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and certain central circulatory system conditions such as pulmonary emboli using continuous aspiration. UPC: Current Stock: . Jawairia Sahar K. Mirza, MBBS This allowed prompt treatment of patients with minimal intensive care unit days and early discharge from the hospital. When performing aspiration, ensure that the Indigo Aspiration Tubing valve is open for only the minimum time needed to remove thrombus. It will reduce service life of the Penumbra ENGINE. Do not advance, retract or use any component of the Indigo Aspiration System against resistance without careful assessment of the cause using fluoroscopy. CAT8 Indigo System Aspiration Catheter - TORQ - 8Fr x 85cm Penumbra System. 22. INDIGO Aspiration System Intended Use Penumbra introduced the Indigo System CAT RX in 2017 for the removal of fresh, soft emboli and thrombi from the coronary and peripheral vasculature. . System Chair, Clinical Research Figure 3. Learn more about Lightning. INDIGO Aspiration System Indication for Use The Penumbra System is a fully-integrated system designed specifically for mechanical thrombectomy, first receiving 510(k) clearance by the FDA in December 2007. Mechanical power aspiration with the Indigo System CAT RX (Penumbra, Inc.), introduced in 2018, continues to gain in popularity as a solution for high thrombus burden in the coronaries. 510 (k) Number. window.dataLayer = window.dataLayer || []; BJC Cardiology Common emitters (such as RFID emitters, security systems, diathermy equipment, and portable transmitters) should not be used in close proximity to the PENUMBRA ENGINE as they can interfere with and result in degradation of the performance of the equipment. She was in a rehab facility prior to this new event recovering from her CVA. Copyright 2023 Penumbra, Inc. All rights reserved. K180412. Contraindications There are no known contraindications. Penumbras IndigoAspiration System can be used to remove emboli and thrombi from vessels of the peripheral arterial and venous systems, and for treatment of pulmonary embolism. The Penumbra IndigoSystem Separatoris intended for use with our Indigo Systems CATfamily of catheters to enable the removal of a wide range of thrombus. Reuse may result in canister cracking or vacuum filter blockages, which may result in the inability to aspirate. Additional Details. Tareq Kass-Hout. Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia; arteriovenous fistula; cardiac injury; cardio-respiratory arrest; death; device malfunction; distal embolization; emboli; excessive blood loss; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; hemoptysis; respiratory failure; thromboembolic events. Brandenton, Florida The patient was brought to the catheterization laboratory for angiography that showed stagnant flow through the saphenous vein graft (SVG; Figure 1). The final angiographic outcome revealed complete revascularization and TIMI 3 flow (Figure 2). We presented our initial experience at the American College of Cardiologys (ACC) 68th Annual Scientific Session, which showed promising results for mechanical power aspiration for thrombus removal during percutaneous intervention using CAT RX.3 This retrospective case series included 59 patients from four institutions around the United States. With a maximised inner diameter of 0.08 (2.1 mm) and a 7 French (2.3 mm) outer diameter, CAT7 is 93% the size of CAT8, now with a lower profile. The Indigo System CAT RX and Penumbra ENGINE aspiration source were crucial to the success of this case. This case illustrates the vast improvement in aspiration technology with an easy-to-deliver, trackable catheter that maintains sustained aspiration for the duration of the procedure. 0 cm from the distal tip. Do not use in an oxygen rich environment. Cardiology; Dental; Emergency & EMT; Endoscopy; Exam & Diagnostic; . Units in stock: 1. For more information on the personal data that is collected by this website, please refer to Penumbras Privacy Notice. Do not use open or damaged packages. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. Distal OD. UPC: Current Stock: This item is out of stock. The following case reports highlight CAT RX in a multitude of unique applications as a primary frontline device to treat patients with high thrombus burden. Lightning 7 expands Penumbra's offering of the Indigo Aspiration System with Intelligent Aspiration for mechanical thrombectomy and is designed for single session arterial thrombus removal. If repositioning of the INDIGO Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard catheter and guidewire techniques. Do not use automated high-pressure contrast injection equipment with the Indigo CAT RX Aspiration Catheter because it may damage the device. Vedantham S, Goldhaber SZ, Julian JA, et al. Do not use the INDIGO Aspiration System with a pump other than the Penumbra Aspiration Pump. waqas.qureshi@umassmemorial.org Unit may overheat and shut off or fail to restart if run for extended periods of time without airflow. CHEETAH will focus on patients presenting with high-grade thrombus burden who receive frontline treatment with CAT RX. Do not advance, retract or use any component of the INDIGO System against resistance without careful assessment of the cause using fluoroscopy. The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. The Indigo Aspiration System is intended for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and certain central circulatory system conditions such as pulmonary emboli using continuous aspiration. The patient had a robust recovery and was discharged to her rehab facility on anticoagulation. N Engl J Med. Maintain a constant infusion of appropriate flush solution. The treatment of arterial and venous thrombus is challenging. The newly available Indigo CAT12 Aspiration Catheter (Penumbra, Inc.) was utilized to perform mechanical thrombectomy of the FV, CFV, and EIV and CIV without the use of thrombolytics . Do not use kinked or damaged devices. Return all damaged devices and packaging to the manufacturer/distributor. Complications from the use of this device in this manner could lead to death, permanent impairment, and/or the need for emergency medical intervention. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. Mechanical power aspiration with a continuous vacuum source and large lumen aspiration catheter was first introduced in the neurovascular space when Penumbra revolutionized thrombus removal for acute ischemic stroke patients. The atraumatic tip and small catheter French size of the CAT8 device allows for easy tracking and maneuvering through the vasculature and selective debulking of thrombus from lobar branches of the pulmonary arterial tree. Lightning comes packaged with the Indigo CAT7, CAT8 or CAT12. The Indigo System Catheter CAT8 was used across 22 sites in the United States in patients with submassive PE who did not receive thrombolytics (98.3%), with a . The Indigo System utilizes the Penumbra ENGINEaspiration source capable of delivering nearly pure, continuous vacuum to our catheters to remove thrombus in vessels of various sizes. It will reduce the service life of the PENUMBRA ENGINE. Placing guidewire too distal in the pulmonary vasculature or excessive manipulation of aspiration/ guiding catheter in the smaller, peripheral, and segmental pulmonary artery branches can result in vessel perforation. Cedars Sinai Medical Center Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower . allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. Do not position the PENUMBRA ENGINE so that it is difficult to remove the power cord.

Lump Under Bruise On Thigh, Leisure Time Products Lamar, Mo, Why Did Josie Shoot Matt In 19 Minutes, Articles C

Leave a Comment

cat8 penumbra catheter

No comments yet. Why don’t you start the discussion?

cat8 penumbra catheter